Refer to Kadant Johnson assembly drawing for part identification and to drawing A37640 for torque specifications. For easy identification, parts used in individual steps are often accompanied with their position in the assembly drawing [e.g. gasket (8B)]. Tighten all fasteners in a star pattern. Certified drawings are available upon request. Dimensions are for reference only and subject to change.
This safety symbol alerts you to risk of death or injury if the instructions are not followed. In all steps, death or injury may result if the machine is not de-energized, depressurized, cooled, and stopped. Death or injury may occur if the product is operated with a fluid type or at a pressure, temperature, or speed that do not meet its specifications. Death or injury may occur if heavy parts and pinch hazards are not handled properly. Follow your company’s safety procedures.
Step 1
Disconnect the piping and anti-rotation device. Remove the head (2).
Loosen the nipple flange (5) and slide the rotary joint away from the journal. Remove the split wedges and nipple flange and save for reuse. Remove the metal gasket (8Q) from the journal flange and discard.
Remove the retaining ring (16B), front guide (6A), and O-ring (31B) from the assembly plate. Remove the assembly consisting of the nipple (4), spring shoulder (3), O-ring (3A), spring (7), and seal ring (6).
Note: The spring shoulder may be stuck on the nipple. Separate the two parts for inspection.
Turn the rotary joint upright and install a new seal ring, with the convex side facing the wear plate. Install the nipple into the body followed by the spring.
Slide the nipple flange over the rotary joint nipple with the taper facing out. Place the split wedges into the recess of the nipple. Slide the nipple flange over the wedges.
Place metal gasket (8Q) into the journal flange. Lift the rotary joint up, slide over the horizontal pipe and into the journal flange. Secure to studs with nuts. An even gap of 1/8" to 3/16" (3 to 5 mm) should remain in between the journal flange and nipple flange.
If you have installation questions or comments to improve these instuctions, we are here to help! Fill out the form below or call 269-278-1715.
R-2800 and 2950 ELSNAHRFZQ
The Kadant Johnson Warranty Kadant Johnson products are built to a high standard of quality. Performance is what you desire: that is what we provide. Kadant Johnson products are warranted against defects in materials and workmanship for a period of one year after the date of shipment. It is expressly understood and agreed that the limit of Kadant Johnson’s liability shall, at Kadant Johnson’s sole option, be the repair or resupply of a like quantity of non-defective product.
Kadant Johnson rotary joints and accessories could be subject to European Pressure Equipment Directive 2014/68/EU (PED). Modifications or changes to rotary joints and/or accessories are only permitted upon approval of Kadant Johnson. Only genuine Kadant parts and original accessories will ensure the safety of these assemblies. The use of other than original parts voids the warranty and will lead to forfeiture of the declaration of conformity and will invalidate any liability for damages cause thereby.