Vacuum Breaker Basics – An interview with Erich Bernhardt
Vacuum breakers provide a simple, dependable way to relieve unwanted vacuum which may develop in a closed vessel or pipeline. Erich Bernhardt, senior applications engineer at Kadant Johnson, provides insight into the basics of vacuum breaker use.
How do vacuum breakers provide vacuum protection?
A vacuum breaker functions like a one-way valve that allows air into the system when a vacuum develops. Under positive pressure, the differential keeps the valve closed. When a vacuum occurs, the higher external atmospheric pressure forces the valve open, allowing air to enter and equalize the pressure.
How do I know I need a vacuum breaker?
In general, any closed system where internal volume can be reduced has the potential to develop a vacuum and should be equipped with a vacuum breaker for protection, unless the vacuum is intentional.
How do you install a vacuum breaker?
Kadant Johnson recommends:
- Putting the vacuum breaker at the highest point in the system
- Installing the vacuum breaker so it does not impinge the flow
- Piping the inlet, the port that air is pulled into, in a safe direction so that it doesn’t drip on anything important when it eventually wears out
- Goose-necking the inlet so that dirt or debris can’t fall into it
- Using a pig-tail below the vacuum breaker to isolate it from heat if the system is really hot
How does position matter?
Proper placement of a vacuum breaker is critical. In liquid systems, it should be installed at the highest point to minimize the risk of water discharge as air is drawn in. In gas or bi-phase systems, the vacuum breaker should be located where it remains dry internally to ensure reliable operation.
The orientation of a vacuum breaker can influence its cracking pressure, the vacuum level at which it begins to open. In most applications, however, this effect is minimal, as systems can typically withstand a greater vacuum than the level required to actuate the vacuum breaker.
What size vacuum breaker do I need?
To size a vacuum breaker, you should know three things:
- The source of the vacuum
- The speed of formation or amount of vacuum – converted to standard cubic feet per minute ideally
- The system’s tolerance for vacuum, i.e., how much vacuum can you have before you get bad effects?
What if the largest size vacuum breaker is too small for my application? Use more than one?
It is completely acceptable to use multiple vacuum breakers to break the vacuum. On rare occasions, the required air flow to break the vacuum may be so large that using multiple vacuum breakers is not an ideal option. In those cases, a large check valve can be used in its place.
If a vacuum breaker is too small, then the valve will not pass the amount of air required to break the vacuum. If a vacuum breaker is too large, then what?
A vacuum breaker that is undersized can still function in certain applications. In these cases, a higher vacuum develops, which increases the driving force for air intake. If the vacuum condition is short-lived, such as steam collapse after a heat exchanger is shut down, and the equipment can tolerate higher vacuum levels, the breaker will eventually admit enough air to recover. This is why smaller vacuum breakers are often used on heat exchangers: the shell can typically withstand significant vacuum, allowing a temporary pressure drop before stabilizing to enable proper condensate drainage.
If a vacuum breaker is too large, we would not foresee any operational issues.
Contact Kadant Johnson for more information about vacuum breakers.