Case Study: Liqui-Mover® Pump Succeeds Where Electric Condensate Pumps Failed
Challenge
A Fortune 100 company heats its multi-building campus from a central boiler house. Condensate was returned to the boilers using electric pumps installed in a sub-basement that flooded once or twice a year, sometimes with as much as eight feet of water. When flooding occurred, the pumps failed, causing heating outages across the campus. The customer needed a condensate return solution that would operate reliably even when fully submerged.
The system must return up to 180,000 pounds per hour of low-conductivity condensate to the boiler room through a six-inch return line. In addition, any solution had to fit within a confined sub-basement and be installable through a five-by-five-foot access opening located 16 feet above the floor.
Solution
Kadant Johnson engineers worked with the customer, their engineering firm, and their boiler management company to design a Liqui-Mover condensate system that could be installed and operated in a small, flooded pit. The solution was a forced-alternating, Float Free™ pump with electronic controls above the flood level. It uses readily available air pressure to pump the condensate, and a guided wave radar to detect condensate levels, eliminating the issues associated with probe sensors and low connectivity condensate. The forced-alternating system uses valves to fill one pump with low-pressure condensate, while air pressure pumps condensate out of the other tank at a higher pressure. They then alternate filling and pumping. This system has few moving parts and maximizes the flow of the six-inch return line by creating continuous flow. For uninterrupted maintenance, a third pump was also included that can be activated remotely.
Results
Kadant Johnson fast-tracked the project to coincide with existing work at the facility. The modular system was engineered and pre-assembled in sections that were lowered through the five-by-five-foot opening. The Liqui-Mover pump was installed over a two week period with Kadant Johnson experts onsite to assist. Whether the sub-basement is dry or flooded, the Liqui-Mover pump will operate continuously for decades.
Related Articles
Tagged with
Author
Share
Talk to an Expert