Case Study: How to Clean a Vacuum Breaker
Vacuum breakers provide a simple, dependable way to relieve any unwanted vacuum condition that may develop in a closed vessel or pipeline. In latent terms, vacuum breakers function as a “one-way-door” that allows air or other mediums to pass through the threshold and seal the door shut, preventing backflow. When installed improperly, they can collect debris on the stainless-steel ball, between the stainless-steel ball and O-ring, and in the cage. The debris reduces the effectiveness of the vacuum breaker, which can lead to catastrophic failure, equipment damage, or serious injury. Proper cleaning is required to remove the debris.
Problem
During routine pre-startup system checks, a customer discovered debris inside several vacuum breakers. To address the issue, they removed the affected vacuum breakers and attempted to clear the obstructions by blowing pressurized air into the cage. However, this method poses a risk: the force of the compressed air can dislodge the internal O-ring, potentially reducing the vacuum breaker’s operational lifespan. A more effective and safer cleaning approach is available, one that preserves the integrity of the O-ring and helps ensure long-term reliability.
Solution
Kadant Johnson recommends cleaning the vacuum breaker using cool, clean tap water to maintain optimal performance. Begin by safely removing the vacuum breaker from its installation. Once removed, use a soft, non-abrasive tool, such as the eraser end of a pencil, to gently press the stainless-steel ball inward against the spring mechanism. This action opens the valve, allowing the low-pressure tap water to flow through and flush out any debris from the cage and ball assembly.
Continue the flushing process until all contaminants have been cleared. Once clean, the vacuum breaker can be reinstalled and returned to service. Following this method helps protect the integrity of the vacuum breaker and ensures reliable long-term operation.

Resources
TestTalk to an Expert